SCARA with three spaced reference spheres and an independent optical measurement head for calibration.

What you need

Use an independent coordinate measurement method and several well-spaced unpowered or safely measured robot configurations.

Illustrative held-out RMS before and after fitting. Before: 1.013 mm; After: 0.408 mm.
Illustrative held-out RMS before and after fitting. Original Academy diagram using illustrative values; not a measured hardware result.
Read the diagram as a data table
Values used in the illustration
Condition or componentmm
Before1.013
After0.408

The calculation

cost = Σ||p_measured,i − FK(q_i, parameters)||²

Parameters may include link lengths and joint-zero offsets. The residual is in squared length units and should be checked on held-out poses.

Worked example

Illustrative numbers. Replace them with your measured inputs.

Illustrative held-out errors of 0.8, 1.0 and 1.2 mm have RMS 1.013 mm. After a hypothetical calibration, 0.3, 0.4 and 0.5 mm give RMS 0.408 mm. These numbers demonstrate reporting, not a measured improvement.

Try it step by step

  1. Measure joint-center geometry and establish reasonable parameter bounds before fitting.
  2. Collect diverse poses with accurate joint readings and independent tool-position measurements, avoiding only straight-arm configurations.
  3. Fit a small identifiable parameter set and inspect whether fitted values remain physically plausible.
  4. Validate on unused poses and compare residual patterns; load-dependent error may require a compliance model rather than altered link lengths.

How to check the result

A useful calibration improves independent residuals without producing implausible geometry or hiding direction-dependent mechanical errors.

Common mistake to avoid

Optimizing many parameters on a few noisy points can overfit. A better training residual is not sufficient evidence of better positioning.